export stereotactic head mask for brainlab system

export stereotactic head mask for brainlab system

Hot products

Disinfectant

Disinfectant

84 disinfectant is a chlorine-containing disinfectant with sodium hypochlorite as the main component...

Read More
Disposable gloves

Disposable gloves

In some industries with high frequency of glove replacement, it is usually recommended to...

Read More
Masks

Masks

The N95 mask is one of nine NIOSH certified particle respirators. N95 is not a specific product name...

Read More
Protective clothing

Protective clothing

Medical protective clothing refers to the protective clothing used by medical personnel...

Read More
Infrared thermometer

Infrared thermometer

In nature, anything above absolute zero radiates infrared energy into the surrounding space...

Read More
Eye protector

Eye protector

A type of protective eyewear that doctors use for homework, also known as an eye mask...

Read More

Founded in 2000, the company has 20 years of experience in the production and processing of medical materials. At present, the company has a sound r & d, production, sales, service system, has become an outstanding manufacturer in China's medical supplies industry, and internationally renowned enterprises to compete in the world market.

Clean has an annual value of $1 billion. Enough to affect the entire Asian region, and even the world's medical supplies production situation..

Covering an area of more than 300,000 square meters, it has 6 domestic first-class production bases and one of the world's largest mask and protective clothing manufacturers.

Clean sales net covers over 160 countries and regions from different continents.




ExacTrac 6.5 - X-Ray Monitoring - Brainlab

The ExacTrac frameless radiosurgery system offers highly accurate delivery of single- or multi-fraction treatment without a conventional, invasive head ring. A patient-friendly head-to-shoulder mask facilitates a streamlined workflow, overcoming the restrictions of frame-based radiosurgery and improving scheduling flexibility for imaging, planning and treatment.

Positioning and Target Control with ExacTrac X ... - Brainlab

The ExacTrac frameless radiosurgery system ensures highly accurate delivery of single or multi-fraction treatment with a patient-friendly mask that facilitates a streamlined workflow. Enhanced cranial immobilization for highly accurate delivery of SRS; Reproducible conformity with a precise non-invasive stereotactic mask system

export stereotactic head mask - mokkendrukken.nl

A.1 BrainLAB stereotactic mask and localizer The BrainLAB mask system provides a noninvasive immobilization setup that allows fixation of . patients treated with cranial stereotactic radiotherapy or radiosurgery. As shown in Fig. 1(a), the system consists of a head rest, a mask ring, vertical posts and a thermoplastic mask. The mask. Cited by 22

ExacTrac® Dynamic - brainlab

Ideal for claustrophobic patients or surface tracking for cranial indications, this mask features a single open-faced anterior sheet and a patient-specific posterior mask. Designed for treatments requiring less accuracy (WBRT, palliative), this mask consists of a single closed-faced anterior sheet and a comfortable carbon base head rest.

Stereotactic Masks — Klarity Medical

Klarity offers stereotactic masks that are compatible with BrainLAB Systems. Our stereotactic masks have been used by clinics worldwide. Klarity masks are an economical stereotactic mask option that offers noninvasive and flexible immobilization. Masks are available in both Klarity White™ and Klarity Green® thermoplastic.

EXACTRAC - Brainlab

Stereotactic sub-millimetric precision can be achieved with the patient’s skull serving as localization geometry, allowing for single fraction radiosurgery.3 The ExacTrac frameless system with its three-piece, non-invasive mask is compatible with couch tops from multiple vendors. 3 Ramakrishna N. et al.

File Size 2MB

Is mask-based stereotactic head-and-neck fixation as ...

The head-and-neck system (BrainLAB, Heimstetten, Germany) has been designed to allow stereotactic treatment down to thoracic vertebrae. Both the combined CT localizer and the target positioner extend over the patient’s shoulders to encompass the neck for CT scanning.

Cited by 21

Stereotactic Radiosurgery Technology and Techniques ...

Stereotactic Radiosurgery Technology and Techniques Delivery Systems and Techniques for Stereotactic Radiosurgery SRS can be delivered with different systems such as linear accelerators, also called LINACs (including robotic systems) and Cobalt-60 systems.

EXACTRAC FRAMELESS RADIOSURGERY - Brainlab

In the last decade, improvements in imaging and computing have led to the development of frameless image-guided radiosurgery, a precise non-invasive variant offering improved patient comfort and treatment flexibility in addition to radiosurgical accuracy2-4.

File Size 226KB

CT Verification of Isocentre Relocatability Using ...

The BrainLab stereotactic system, in conjunction with the BrainScan V.4.01 planning system, has been used for stereotactic treatment at the Tuen Mun Hospital since April 1998. Thirty-seven stereotactic cases with all together 590 applications were involved in the study.

Cited by 9

Stereotactic Mask for Brainlab System(id:9526210) Product ...

Stereotactic Mask for Brainlab System(id:9526210), View quality brainlab masks, thermoplastic masks, radiation therapy masks details from Klarity Medical & Equipment Co., Ltd. storefront on EC21. Buy best Stereotactic Mask for Brainlab System with escrow buyer protection.

User rating 5/5

Evaluation of the setup accuracy of a stereotactic ...

A.1 BrainLAB stereotactic mask and localizer The BrainLAB mask system provides a noninvasive immobilization setup that allows fixation of . patients treated with cranial stereotactic radiotherapy or radiosurgery. As shown in Fig. 1(a), the system consists of a head rest, a mask ring, vertical posts and a thermoplastic mask. The mask

Cited by 22

China Klarity Stereotactic Head Mask for Thermoplastic ...

Klarity now offers stereotactic masks for BrainLAB systems in standard white and Klarity Green. Each mask set contains front, middle and rear masks, support strip, and bag of loose pellets. - Noninvasive and flexible immobilization - Economical stereotactic mask option - …

Frameless linac-based stereotactic radiosurgery (SRS) for ...

A commercial stereotactic mask fixation system (BrainLab) was used for patient immobilization. A computerized tomography (CT) scan obtained immediately before SRS was used to evaluate the accuracy of patient repositioning in the mask by comparing the isocenter position to the isocenter position established in the planning CT.

Cited by 59

What is Linear Accelerator Stereotactic Radiosurgery ...

The traditional way of securing the patient’s head in stereotactic radiosurgery is by fastening an invasive head frame to the skull with sharp-tipped screws. Even though the head frame is effective for keeping patients immobile during treatment, some patients find head frame placement inconvenient and sometimes painful.

Purpose

The 3-point thermoplastic Orfit mask and BrainLAB stereotactic mask provide immobilization of the head in fractionated radiotherapy. The purpose of this study was to compare the setup accuracy of these two masks using pre-treatment kV-CBCT and ExacTrac®. Methods Both BrainLab and Orfit masks are currently used in our institution.

(PDF) Evaluation of the setup accuracy of a stereotactic ...

Evaluation of the setup accuracy of a stereotactic radiotherapy head immobilization mask system using kV on-board imaging Article (PDF Available) in Journal of Applied Clinical Medical Physics 11 ...

Fractionated stereotactic radiotherapy for skull base ...

Introduction. Stereotactic radiation techniques in form of radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT) are frequently employed in patients with skull base tumors in order to increase the precision of radiotherapy and decrease the potential long-term toxicity of treatment [1-3].FSRT using a commercially available stereotactic mask fixation system (BrainLAB AG) has been ...

Cited by 150

Quantitative evaluation of patient setup uncertainty of ...

6D Brainlab ExacTrac system (Brainlab, Inc, Westchester, IL) is investigated. This system uses . a noninvasive thermoplastic immobilization mask and stereotactic localizer which increases patient comfort and allows faster patient setup and fractionated treatment as compared to inva - sive immobilization systems.

Cited by 5

brainlab thermoplastic head mask, brainlab thermoplastic ...

5 brainlab thermoplastic head mask products are offered for sale by suppliers on , of which medical-ray protective products accounts for 100%. A wide variety of brainlab thermoplastic head mask options are available to you, There are 5 suppliers who sells brainlab thermoplastic head mask on , mainly located in Asia.

Clinical accuracy of ExacTrac intracranial frameless ...

The ExacTrac intracranial frameless stereotactic system spatial accuracy is adequate for clinical practice, and with the same pass criteria, SRT is more accurate than SRS. They now use frameless ...

Spine Stereotactic Body Radiation Therapy Residual Setup ...

The red points represent where treatment is being delivered within a box, with each side measuring 1.5 mm; the red clouds demonstrate volumetric accuracy and precision of the treatment. There was a significantly greater difference in the average 3D variance of the BodyFIX as compared to the BrainLAB head and shoulder mask immobilization system.

Cureus A Mask Immobilization Study Comparison Between ...

In fact, in 243/324 (75%) of the obtained images revealed the shift from the isocenter of < 1.2 mm for the Civco mask and < 0.6 mm for the Brainlab mask. Conclusions Our data demonstrated that the BrainLab immobilization mask system provides better positioning accuracy and smaller shifts from the isocenter during treatment in a statistically ...

Author Nedialkova L, Sabbas A, Ostenson J, Trichter S, Kulidzhanov F, Mckenna J, Saleh K, Parashar B, Werni...

[Improved patient repositioning accuracy by integrating an ...

MATERIAL AND METHODS 29 patients were treated with stereotactic radiotherapy of the head. Immobilization was provided by a two layer thermoplastic mask system (BrainLab). 18 of these patients received an additional custom made fixation either of the upper jaw (OKF) or of the mandibula (UKF).

Cited by 17

Quantitative evaluation of patient setup uncertainty of ...

May 08, 2016 · All these patients are immobilized with rigid head‐and‐neck masks, simulated with Brainlab localizer and planned with iPlan treatment planning system. Stereoscopic X‐ray images (XC) are acquired and registered to corresponding digitally reconstructed radiographs using bony‐anatomy matching to calculate 6D translational and rotational ...

Cited by 5

Is mask-based stereotactic head-and-neck fixation as ...

Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy? Article in International Journal of Radiation OncologyBiologyPhysics 66(4 ...

Positioning Features in Current Immobilization Systems

Positioning Features in Current Immobilization Systems Josh Evans, Ph.D. Virginia Commonwealth University Richmond, VA. Disclosures ... “The TALON removable head frame system for stereotactic radiosurgery/radi otherapy measurement of the ... – BrainLab 3 piece mask – Elekta eXtend. BrainLab mask • Non-invasive, relocatable device ...

File Size 2MB

Evaluations of the setup discrepancy between BrainLAB 6D ...

The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were …

Cited by 5

Brainlab ExacTrac-Style Stereotactic Masks

Brainlab ExacTrac-Style Stereotactic Masks IOS's Brainlab ExacTrac-Style Stereotactic Masks are a cost-effective, extremely high quality mask system designed for the Brainlab …

ExacTrac® Dynamic - brainlab

Ideal for claustrophobic patients or surface tracking for cranial indications, this mask features a single open-faced anterior sheet and a patient-specific posterior mask. Designed for treatments requiring less accuracy (WBRT, palliative), this mask consists of a single closed-faced anterior sheet and a comfortable carbon base head rest.

Stereotactic Masks - AEP

Klarity offers stereotactic masks for BrainLAB systems. Our stereotacitc masks have been used by clinics worldwide. Klarity’s reduced shrinkage and non-stick material are perfect for BrainLab systems. Order by Set. Two-part masking system Compatible with standard BrainLAB systems Economical stereotactic mask option Noninvasive and flexible immobilization

Klarity Stereotactic Head & Shoulder Mask for Brainlab System

Klarity Stereotactic Head & Shoulder Mask For Brainlab System , Find Complete Details about Klarity Stereotactic Head & Shoulder Mask For Brainlab System,Brainlab Head Mask,Low Temperature Thermoplastic,Brainlab Thermoplastic Mask from Medical-Ray Protective Products Supplier or Manufacturer-Klarity Medical & Equipment (GZ) Co., Ltd.

Positioning Accuracy in Stereotactic Radiotherapy Using a ...

For cranial patients receiving stereotactic radiotherapy, we use the Exactrac stereoscopic X-ray system to optimize patient positioning. Patients are immobilized with the BrainLAB Mask System (BrainLAB, Feldkirchen, Germany). We have developed an adapter to this system that accommodates a vacuum mouth piece (VMP).

Klarity Thermoplastic Mask Stereotactic Mask For Brainlab ...

Klarity Thermoplastic Mask Stereotactic Mask For Brainlab System , Find Complete Details about Klarity Thermoplastic Mask Stereotactic Mask For Brainlab System,Brainlab Thermoplastic Mask,Thermoplastic Mask For Head Immobilization,Radiotherapy Patient Positioning And Fixation from Medical-Ray Protective Products Supplier or Manufacturer-Klarity Medical & Equipment (GZ) Co., Ltd.

INTER‐ AND INTRAFRACTION MOTION FOR STEREOTACTIC ...

Jun 25, 2015 · inter‐ and intrafraction motion for stereotactic radiosurgery in dogs and cats using a modified brainlab frameless stereotactic mask system Sonja Dieterich Department of Radiation Oncology, UC Davis School of Medicine, Sacramento, CA

Evaluations of the setup discrepancy between BrainLAB …

to fix the head with the standard BrainLAB systems. The stereotactic mask set was composed of 5 components including a top mask, middle mask, rear mask, package of loose pellets, and Fig 1. Image of the patient setup with ExacTrac frameless radiosurgery positioning array (BrainLAB …

SU‐FF‐T‐346 Measurement of Surface Dose Increase From ...

Purpose To evaluate setup accuracy of the BrainLAB stereotactic radiotherapy head immobilization mask using orthogonal projections from on‐board imaging. Materials and Methods Eight patients were s...

Patient Position Reproducibility in Fractionated ...

Apr 01, 2001 · Read "Patient Position Reproducibility in Fractionated Stereotactically Guided Conformal Radiotherapy Using the BrainLab® Mask System, Strahlentherapie und Onkologie" on DeepDyve, the largest online rental service for scholarly research with thousands of …

Head & Neck Positioning - civcort

The first step in choosing the right thermoplastic mask is determining which patient positioning and fixation system appeals to you. Our ZENTEC™ and Standard White masks are available in Type-S™ and Uni-frame ® while Mastercast Pro™ and Posicast ® are available for the Posifix ® System. Use the filtering options on the left to narrow ...

The accuracy of frameless stereotactic intracranial ...

Purpose. To determine the accuracy of frameless stereotactic radiosurgery using the BrainLAB ExacTrac system and robotic couch by measuring the individual contributions such as the accuracy of the imaging and couch correction system, the linkage between this system and the linac isocenter and the possible intrafraction motion of the patient in the frameless mask.

Measurement of repositioning accuracy during fractionated ...

Therefore, the repositioning accuracy of our mask system could be regarded as relatively great. In conclusion, the removable noninvasive fixation mask (Klarity Medical & Equipment Co., Ltd.) for the BrainLAB SRT system had a relatively high repositioning accuracy for fractionated SRT.

Evaluations of the setup discrepancy between BrainLAB 6D ...

The objective of this study was to evaluate the setup discrepancy between BrainLAB 6 degree-of-freedom (6D) ExacTrac and cone-beam computed tomography (CBCT) used with the imaging guidance system Novalis Tx for intracranial stereotactic radiosurgery. We included 107 consecutive patients for whom white stereotactic head frame masks (R408; Clarity Medical Products, Newark, OH) were …

Positioning Accuracy in Stereotactic Radiotherapy Using a ...

Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning

IFU — Klarity Medical

Stereotactic for BrainLab System. Elekta Fraxion and Icon. Elekta HeadStep. P-Type. V-Type. Proton Mask for Qfix BoS™ Hip Fix . Klarity Cushions™ Klarity Cushions™ Shell System™ Ovens. AirFlow™ Oven. Classic Oven. Mini-Oven . Vacuum Bags. Vacuum Bags. Vacuum Pump . Baseplates and Overlays. Optek Overlay. Supine Breast System. WingSpan ...

Frameless linac-based stereotactic ... - Radiation Oncology

Nov 16, 2011 · Different frameless stereotactic systems, including infrared camera guidance , dental [18–20], implanted fiducial markers [21, 22], and mask fixation system [6–12] have been developed in the last two decades. In our study using a mask-based stereotactic system we have evaluated the accuracy of isocenter relocation by repeat CT scans.

CT Verification of Isocentre Relocatability Using ...

For stereotactic radiotherapy of brain metastases a commercial head mask fixation device based on thermoplastic materials (BrainLAB) was used. A two-step planning-treatment procedure was performed.

Evaluation of the setup accuracy of a stereotactic ...

A.1 BrainLAB stereotactic mask and localizer. The BrainLAB mask system provides a noninvasive immobilization setup that allows fixation of patients treated with cranial stereotactic radiotherapy or radiosurgery. As shown in Fig. 1(a), the system consists of a head rest, a mask ring, vertical posts and a thermoplastic mask. The mask ring is ...

Fractionated stereotactic radiotherapy for skull base ...

Jan 13, 2010 · Stereotactic radiation techniques in form of radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT) are frequently employed in patients with skull base tumors in order to increase the precision of radiotherapy and decrease the potential long-term toxicity of treatment [1–3].FSRT using a commercially available stereotactic mask fixation system (BrainLAB AG) has …

Evaluation of setup uncertainties for single-fraction SRS ...

The setup uncertainties for each mask with the stereotactic localizing system had an asymmetric offset towards the positive AP direction. The A-mask-creation method, which is capable of covering the top of the patient's head, is superior to that for the R-mask, so the use of the A-mask is encouraged for SF-SRS to reduce the setup uncertainties.

How Does Spine Radiation Therapy Work? - Brainlab

2 van Santvoort, Jan et al. Positioning Accuracy in Stereotactic Radiotherapy Using a Mask System With Added Vacuum Mouth Piece and Stereoscopic X-Ray Positioning Int J Radiat Oncol Biol Phys, Volume 72, Issue 1, 261 – 267. 3 Lamba, Michael et al. Evaluation of Image-Guided Positioning for Frameless Intracranial Radiosurgery. Int J Radiat ...

INTER‐ AND INTRAFRACTION MOTION FOR STEREOTACTIC ...

Precise and accurate patient positioning is necessary when doing stereotactic radiosurgery (SRS) to ensure adequate dosing to the tumor and sparing of normal tissues. This prospective cross‐section...

Estimation of patient setup uncertainty using BrainLAB ...

The BrainLAB ExacTrac X-Ray 6D stereotactic IGRT system ... Patient immobilization was achieved by using the commercially available BrainLAB head . mask fixation system. The characteristics of this system have been previously described.(12) During the planning visit, a thermoplastic mask was fabricated to conform precisely to the ...

Dosimetric effects of positioning shifts using 6D ...

It indicates that the initial Brainlab positioning based on rigidity of the mask frame is not sufficient for accurate stereotactic positioning. Submillimeter accuracy was achieved with kV X‐ray verification and random errors (SD) were less than 0.3 mm ( Table 2 ) using our Brainlab frameless stereotactic system.

SU-E-T-659 Quantitative Evaluation of Patient Setup ...

All patients were simulated with a rigid head-and-neck mask and the BrainLAB localizer. CT images were transferred to the IPLAN treatment planning system where optimized plans were generated using stereotactic reference frame based on the localizer. The patients were setup initially with infrared (IR) positioning ExacTrac system.

Brainlab iPlan/m3-Micro-MLC Stereotactic Radiotherapy ...

Brainlab manufacturer specifications for iPlan/m3-Micro-MLC Stereotactic Radiotherapy System on MedWOW medical equipment global marketplace.

Is mask-based stereotactic head-and-neck fixation as ...

Nov 15, 2006 · Read "Is mask-based stereotactic head-and-neck fixation as precise as stereotactic head fixation for precision radiotherapy?, International Journal of Radiation Oncology Biology Physics" on DeepDyve, the largest online rental service for scholarly research with thousands of academic publications available at your fingertips.

export o type pediatric mask 3 point head mask

China Point Head Mask, Point Head Mask Manufacturers ... Type the keywords you're interested in such as Point Head Mask and make direct contact with any desirable suppliers / manufacturers / wholesalers for more important details or find similar choices that are thermoplastic mask, cheap radiotherapy mask…

Top